Documentation of pulmonary function testing

The results of spirometry that are used for adjudication, under the 103.02 A and B, 103.03, and 103.04 of these listings should be expressed in liters (L), body temperature and pressure saturated with water vapor (BTPS). The reported one-second forced expiratory volume (FEV1) and forced vital capacity (FVC) should represent the largest of at least three satisfactory forced expiratory maneuvers. Two of the satisfactory spirograms should be reproducible for both pre-bronchodilator tests and, if indicated, postbronchodilator tests. A value is considered reproducible if it does not differ from the largest value by more than 5 percent or 0. 1 L, whichever is greater. The highest values of the FEV1, and FVC, whether from the same or different tracings, should be used to assess the severity of the respiratory impairment.

Peak flow should be achieved early in expiration, and the spirogram should have a smooth contour with gradually decreasing flow throughout expiration. The zero time for measurement of the FEV1 and FVC, if not distinct, should be derived by linear back-extrapolation of peak flow to zero volume. A spirogram is satisfactory for measurement of the FEV1 if the expiratory volume at the back-extrapolated zero time is less than 5 percent of the FVC or 0.1 L, whichever is greater. The spirogram is satisfactory for measurement of the FVC if maximal expiratory effort continues for at least 6 seconds, or if there is a plateau in the volume-time curve with no detectable change in expired volume (VE) during the last 2 seconds of maximal expiratory effort.

Spirometry should be repeated after administration of an aerosolized bronchodilator under supervision of the testing personnel if the prebronchodilator FEV1 value is less than the appropriate reference value in table I or III, as appropriate. If a bronchodilator is not administered, the reason should be clearly stated in the report. Pulmonary function studies should not be performed unless the clinical status is stable (e.g., the child is not having an asthmatic attack or suffering from an acute respiratory infection or other chronic illness.). Wheezing is common in asthma, chronic bronchitis, or chronic obstructive pulmonary disease and does not preclude testing.

Pulmonary function studies performed to assess airflow obstruction without testing after bronchodilators cannot be used to assess levels of impairment in the range that prevents a child from performing age appropriate activities unless the use of bronchodilators is contraindicated. Post-bronchodilator testing, should be performed 10 minutes after bronchodilator administration. The dose and name of the bronchodilator administered should be specified. The values in 103.02 and 103.04 must only be used as criteria for the level of ventilatory impairment that exists during the child's most stable state of health (i.e., any period in time except during or shortly after an exacerbation).

The appropriately labeled spirometric tracing, showing the child' s name, date of testing, distance per second on the abscissa and the distance per liter (L) on the ordinate, must be incorporated into the file. The manufacturer and model number of the device used to measure and record the spirogram should be stated. The testing device must accurately measure both time and volume, the latter to within 1 percent of a 3 L calibrating volume. If the spirogram was generated by any means other than direct pen linkage to a mechanical displacement-type spirometer, the testing device must have had a recorded calibration performed previously on the day of the spirometric measurement.

If the spirometer directly measures flow, and volume is derived by electronic integration, the linearity of the device must be documented by recording volume calibrations at three different flow rates of approximately 30 L/min (3 L/6 sec), 60 L/min (3 L/3 sec), and 180 L/min (3 L/sec). The volume calibrations should agree to within 1 percent of a 3 L calibrating volume. The proximity of the flow sensor to the child should be noted, and it should be stated whether or not a BTPS correction factor was used for the calibration recordings and for the child's actual spirograms.

The spirogram must be recorded at a speed of at least 20 mm/sec, and the recording device must provide a volume excursion of at least 10 mm/L. If reproductions of the original spirometric tracings are submitted, they must be legible and have a time scale of at least 20 mm/sec and a volume scale of at least 10 mm/L to permit independent measurements. Calculation of FEV1 from a flow-volume tracing is not acceptable; i.e., the spirogram and calibrations must be presented in a volume-time format at a speed of at least 20 mm/sec and a volume excursion of at least 10 mm/L to permit independent evaluation.

A statement should be made in the pulmonary function test report of the child's ability to understand directions, as well as his or her effort and cooperation in performing the pulmonary function tests.

Purchase of a pulmonary function test is appropriate only when the child is capable of performing reproducible forced expiratory maneuvers. This capability usually occurs around age 6. Purchase of a pulmonary function test may be appropriate when there is a question of whether an impairment meets or is equivalent in severity to a listing, and the claim cannot otherwise be favorably decided.

The pulmonary function tables in 103.02 and 103.04 are based on measurement of standing height without shoes. If a child has marked spinal deformities (e.g. kyphoscoliosis), the measured span between the fingertips with the upper extremities abducted 90 degrees should be substituted for height when this measurement is greater than the standing height without shoes.

Call Now!

If you wish to hire a licensed Attorney to help win your claim, call Social Security Professionals.

Call Social Security Professionals now to discuss your claim for free!

You need no money to hire Attorney Donald H. Peters

(248) 549-3485
FREE CONSULTATION

Call Social Security Professionals now to discuss your claim for free

You need no money to hire Attorney Donald H. Peters

(248) 549-3485
FREE CONSULTATION

Southfield Lawyer Donald Peters of the Law Office of Donald H. Peters, P.C. in Southfield, Michigan, handles Social Security Disability claims throughout Michigan and in the Tri-County Metro Detroit area including Detroit, Southfield, Novi, Warren, Royal Oak, Roseville, Livonia, Mount Clemens, Sterling Heights, Farmington Hills, Birmingham, Berkley, Oak Park, West Bloomfield, Ann Arbor, Eastpointe, Waterford, Flint, Canton, Taylor, Romulus, Westland, Clinton Township, Troy, Dearborn, Brighton, Howell, Pontiac, Rochester Hills,  as well as Wayne County, Oakland County, Macomb County, Ingham County, and Livingston County, Michigan.

Disclaimer

Material presented on the Social Security Professionals website is intended for general informational purposes only.  It is not intended as professional advice in any manner and should not be construed as such.  Individuals should never act upon any information provided in a website except that you should seek the advice of an Attorney. 

For the most up to date content regarding Social Security Disability please reference the Social Security Administration's website.

You may call Social Security Professionals and discuss your claim for free at:

(248) 549-3485